| + | ===== Updated a Linked Database for 2Ring ===== | ||
| + | |||
| + | *Create two new linked databases on the 2Ring Server to connect to the A and B side UCCE AW databases. | ||
| + | *Setup a new linked database | ||
| + | *{{: | ||
| + | |||
| + | *Enter server hostname of the UCCE AW Server and select the SQL Server buttton | ||
| + | *{{: | ||
| + | |||
| + | *in the Security tab, select the "Be made using this security context" | ||
| + | *{{: | ||
| + | |||
| + | *Hit Okay and confirm a Connection Test | ||
| + | *{{: | ||
| + | |||
| + | *The test should be successful. | ||
| + | *{{: | ||
| + | |||
| + | *Update the linked database on the 2Ring Admin interface | ||
| + | *{{: | ||
| + | |||
| + | *Restart the 2Ring Connector Service | ||
| + | * {{: | ||
| + | |||
| + | |||
| + | |||
| + | |||